This paper discusses a female patient with severe aortic stenosis, who was preoperatively assessed to be at high risk of left coronary artery occlusion, but developed complete occlusion of the right coronary artery during the procedure of transcatheter aortic valve replacement, leading to hemodynamic disorder. Surgical treatment under emergency cardiopulmonary bypass played a critical role in rescuing the patient.
One of its primary surgical treatments of tricuspid regurgitation is tricuspid valve biological valve replacement. Catheter tricuspid valve-in-valve implantation is a novel interventional alternative for biological valve failure. The non-invasive lung fluid measuring device remote dielectric sensing (ReDSTM) has been increasingly incorporated into clinical practice as a means of monitoring chronic heart failure in recent years. This report describes the process and outcomes of the first instance of perioperative lung fluid volume evaluation following transcatheter tricuspid valve implantation utilizing ReDSTM technology. The patient has a short-term, substantial increase in postoperative lung fluid volume as compared to baseline.
Objective To investigate the risk factors and the prevention and cure methods of ischemic stroke during low intensity anticoagulation therapy after mechanical heart valve replacement. Methods From March 2004 to July 2008,twentythree patients with ischemic stroke after mechanical heart valve replacement had been researched(ischemic stroke group). One hundred and twenty patients who had undergone mechanical heart valve replacement were randomly chosen in the same period as control group. Gender, age, the dose of warfarin , anticoagulation intensity(INR), INR review interval, left atrial diameter and heart rhythm were compared between the two groups, and the risk factors of ischemic stroke were analyzed by logistic regression analysis. Results (1) Patients in ischemic stroke group all discharged from hospital after treatment, and they were followed up for 1 month-3 years after discharged. All the patients’ neurological complications improved obviously, and no recurrent embolism and severe hemorrhage was found. (2) There was no statistical significance between two groups in gender, age and the dose of warfarin(Pgt;0.05). (3) Nonconditional logistic regression analysis on influence factors showed that atrial fibrillation(P=0.000), left atrial enlargement(P=0.002), low anticoagulation intensity(P=0.012) and longtime INR review interval(P=0.047)were the risk factors of ischemic stroke during low intensity anticoagulation therapy after mechanical heart valve replacement. Conclusions (1)The prognosis of ischemic stroke during low intensity anticoagulation therapy after mechanical heart valve replacement is better than that of intracranial hemorrhage, and the occurrence of ischemic stroke is related to many risk factors. (2)The influences of risk factors should be minimized in order to avoid ischemic stroke. (3) Early low intensity anticoagulation therapy is safe and effective for patients with ischemic stroke after heart valve replacement.
ObjectiveTo analyze the factors influencing the occurrence of subclinical leaflet thrombosis (SLT) after percutaneous aortic valve replacement using balloon-expandable valve (Sapien3, S3). Methods Retrospective analysis was made on 62 patients with severe aortic stenosis undergoing percutaneous aortic valve replacement using S3 in our center from September 2020 to June 2022. Patients with a history of vascular atherosclerosis or with significant increase or insignificant decrease of aortic valve flow or gradient pressure during follow-up were selected for CT examination. Results A total of 26 patients were finally included, with an average age of 70.31±8.90 years, and the male proportion was higher (n=15, 57.69%). Among them, 5 patients had SLT. Compared with the non-SLT group, patients in the SLT group were older (68.52±8.80 years vs. 77.80±4.66 years, P=0.007). The age factor (≥75 years) and the diameter of the ascending aorta were associated with SLT (both P<0.05). Conclusion The incidence of SLT is higher in the elderly patients. It is speculated that SLT is related to the characteristics of short balloon dilation valves and low blood flow dynamics of valve racks.
After nearly two decades of application and development, the clinical efficacy of transcatheter aortic valve replacement (TAVR) has been continuously improved and demonstrated. Due to the expansion of indications of TAVR, the frequency of encountering patients with mixed valvular diseases increases greatly, particularly the moderate to severe mitral regurgitation combined with aortic stenosis. Multiple registry studies suggest that the incidence of significant mitral regurgitation is approximately 13% to 74% in patients who undergo TAVR. Some studies have reported that moderate to severe MR is associated with higher mortality, while simultaneous aortic and mitral valve surgery is associated with significantly higher surgical risk. Therefore, the optimal treatment strategy for this special patient group remains uncertain. With the further development of transcatheter therapy, staged surgery may be a feasible solution. However, there is currently a lack of evidence-based support such as randomized clinical trials. This review aims to report and evaluate relevant existing research data to help clinicians make optimal treatment decisions for this specific patient populations.
ObjectiveTo compare the in-hospital outcomes of transapical transcatheter aortic valve replacement (TA-TAVR) for bicuspid aortic valve (BAV) patients and tricuspid aortic valve (TAV) patients. MethodsPatients (including BAV and TAV patients) who underwent TA-TAVR with the J-ValveTM in West China Hospital from July 2014 to July 2020 were included consecutively. The clinical outcomes of the patients were analyzed. ResultsA total of 354 patients were included in the study, 75 in the BAV group and 279 in the TAV group. There were 229 males and 125 females with a mean age of 72.2±6.0 years. No death occurred during the procedure, and the overall technical success rate was 97.7%. The all-cause in-hospital mortality rate was 1.4%. Twenty (26.7%) patients with BAV and 46 (16.5%) patients with TAV had mild or higher perivalvular leaks immediately after the procedure. No patients with BAV required permanent pacemaker implantation postoperatively, while 13 (4.7%) TAV patients required permanent pacemaker implantation, with an overall pacemaker implantation rate of 3.7%. One (1.3%) BAV patient and 7 (2.5%) TAV patients developed acute kidney injury postoperatively. One (1.3%) BAV patient and 1 (0.4%) TAV patient developed perioperative myocardial infarction. The average postoperative hospital stay was 7.6±3.6 d for BAV patients and 8.6±6.1 d for TAV patients. There was no statistical difference in primary or secondary in-hospital outcomes between BAV and TAV patients (P>0.05). ConclusionCompared to TAV patients, BAV patients have similar in-hospital outcomes, with a low incidence of adverse clinical outcomes, which provides preliminary evidence for its implementation in Chinese patients with a high proportion of BAV.
ObjectiveTo explore the clinical effect of LuX-Valve implantation in patients with severe tricuspid regurgitation (TR) and review articles about similar devices.MethodsWe reported the data of a 58-year-old male patient with severe TR, who was hospitalized on March 17th, 2020 because of “abdominal distention and edema for 5 years”, and then received LuX-Valve implantation in the Department of Cardiovascular Surgery of Changhai Hospital, Naval Medical University. Articles about transcatheter tricuspid valve replacement were reviewed in PubMed according to the key words including “transcatheter tricuspid valve replacement” “TTVR” and “transcatheter tricuspid valve intervention”.ResultsThe patient with severe TR received LuX-Valve implantation under general anesthesia and the guidance of digital subtraction angiography and transesophageal echocardiography. The patient’s TR was totally corrected after implantation and postoperative one-month follow-up showed well clinical effects. The result of literature review showed that there were two similar devices and both had been implanted in TR patients.ConclusionLuX-Valve is an effective and reliable transcatheter tricuspid valve replacement device.
ObjectiveTo summarize the efficacy of different anticoagulation methods during perioperative period of non-cardiac surgery after cardiac valve replacement and to compare the postoperative bleeding-related complications and embolization-related complications.MethodsRetrospective analysis of clinical data of 56 patients who underwent non-cardiac surgery after cardiac valve replacement in our hospital from January 2016 to January 2018 was conducted. There were 27 males and 29 females, aged 19-75 (53.56±13.94) years. According to different anticoagulation methods during perioperative period, the patients were divided into a bridging group (32 patients) and a non-bridging group (24 patients). The postoperative hospital stay, the number of patients needing postoperative blood transfusions, bleeding-related complications and embolization-related complications were compared between the two groups. According to the patient’s perioperative embolization risk, each group of patients were divided into a high-risk subgroup, middle-risk subgroup, and low-risk subgroup, and the bleeding-related complications and embolization-related complications in each subgroup were compared.ResultsThe postoperative hospital stay in the bridging group was significantly longer than that in the non-bridging group (P<0.05), but there was no significant difference in the number of patients needing postoperative blood transfusions, overall bleeding-related complications and embolization-related complications between the two groups (P>0.05). Subgroup analysis was performed according to the degree of embolization risk in the perioperative period. The incidence of bleeding-related complications of the non-bridging group in the high-risk subgroup was significantly higher than that in the high-risk subgroup of the bridging group (P<0.05). The incidence of bleeding-related complications in the bridging group was similar to that of embolization-related complications, while the rate of bleeding-related complications in the non-bridging group was 7 times higher than that of embolization-related complications.ConclusionBridging anticoagulation increases the length of postoperative hospital stay, but for patients with high risk factors for embolization, it is more beneficial than continuing oral warfarin during the perioperative period. The incidence of bleeding-related complications associated with continued warfarin therapy is significantly higher than that of embolization-related complications, and hemostatic drugs can be given necessarily.
Functional tricuspid regurgitation is referred to tricuspid regurgitation due to enlargement of right ventricular and dilation of tricuspid annulus. Patients with chronic progressive tricuspid regurgitation have poor prognosis, poor quality of life and heavy economic burden. This article provides a comprehensive review of functional tricuspid regurgitation in terms of anatomical basis, pathological stage, imaging assessment and surgical decision making.
ObjectiveTo evaluate the changes of left ventricular morphology and contractile function of patients with mitral stenosis and small left ventricle after mitral valve replacement. MethodsStudies on the changes of left ventricular morphology and contractile function of patients with mitral stenosis and small left ventricle after mitral valve replacement were searched from the databases of Wangfang, VIP, CNKI, PubMed, Elsevier Science Direct, and Cochrane Library from establishment to January 2015. Quality of articles was evaluated. Relevant data were extracted from eligible studies to conduct meta-analysis. Mean differences (MD) of left ventricle end-diastolic volume index (LVEDVI), left ventricle end-diastolic diameter (LVEDD), left ventricular ejection fraction (LVEF) and left ventricular fraction shortening (LVFS) between the preoperative and the postoperative value from eligible studies were analyzed and pooled, and their 95% confidence intervals (CI) were calculated. R2.15.3 software was applied for statistical analysis. ResultsEight eligible studies involving 446 patients were analyzed in the study. The quality of included literature was high. The results of meta-analysis showed that LVEDVI and LVEDD increased by 14.51 ml/m2 with 95%CI -22.78 to -6.25 (P<0.01) and 4.88 mm with 95%CI -10.85 to 1.09 (P=0.11) respectively at 2 weeks postoperatively compared with preoperative value. LVEF decreased by 3.05% with 95%CI -3.02% to 9.12% (P=0.32) while LVFS increased by 1.16% with 95%CI -4.83% to 2.50% (P=0.53) at 2 weeks postoperatively. Compared with preoperative value, LVEDVI and LVEDD markedly increased by 16.11 ml/m2 with 95%CI -20.32 to -11.90 (P<0.01) and 10.56 mm with 95%CI -11.52 to -9.60 (P<0.01) respectively at 6 months postoperatively. LVEF and LVFS increased by 7.69% with 95%CI -17.18% to 1.8% (P=0.11) and 6.21% with 95%CI -10.07% to -2.36% (P<0.01) respectively at 6 months postoperatively compared with preoperative value. ConclusionLeft ventricular morphology and contractile function of patients with mitral stenosis and small left ventricle recovers well after mitral valve replacement.