west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "valve replacement" 312 results
  • Safety and effectiveness of the SAPIEN 3 transcatheter heart valve in the treatment of severe aortic stenosis: Early clinical outcomes of a multicenter study in China

    Objective To evaluate the safety and efficacy of transcatheter aortic valve replacement (TAVR) using the SAPIEN 3 system. MethodsThis was a prospective, multicenter, single arm study in 4 centers in China. The clinical data of 50 patients with high-risk symptomatic severe aortic stenosis who underwent TAVR using the SAPIEN 3 system from June 2017 to June 2019 were analyzed, including 27 males and 23 females aged 76.8±6.1 years. ResultsThe Society of Thoracic Surgeon score was 6.0%±2.8%. Totally, 20.0% of patients had severe bicuspid aortic stenosis. The operation time was 41.8±16.5 min and the hospital stay time was 8.5±5.0 d. At the postoperative 30-day follow-up, no all-cause mortality occurred and the device success rate was 89.5%. Major vascular complications occurred in one (2.0%) patient, stroke in one (2.0%) patient, new pacemaker implantation in one (2.0%) patient, as well as coronary artery obstruction in one (2.0%) patient. There was no moderate or moderate/severe paravalvular leak. The aortic pressure gradient was decreased from 49.2±16.2 mm Hg before the operation to 12.4±4.6 mm Hg at the postoperative 30-day follow-up, and the valvular area was increased from 0.6±0.3 cm2 to 1.3±0.3 cm2 (P<0.01). Moreover, the New York Heart Association classification in 83.7% of the patients was improved during the follow-up. ConclusionThis pre-marketing multicenter study has demonstrated the safety and effectiveness of transfemoral TAVR with the SAPIEN 3 transcatheter valve system in Chinese aortic stenosis patients at high risk for surgery.

    Release date:2022-05-23 10:52 Export PDF Favorites Scan
  • A right coronary artery occlusion after transcatheter aortic valve replacement

    This paper discusses a female patient with severe aortic stenosis, who was preoperatively assessed to be at high risk of left coronary artery occlusion, but developed complete occlusion of the right coronary artery during the procedure of transcatheter aortic valve replacement, leading to hemodynamic disorder. Surgical treatment under emergency cardiopulmonary bypass played a critical role in rescuing the patient.

    Release date:2020-10-26 03:00 Export PDF Favorites Scan
  • Emergency transcatheter aortic valve replacement for surgical bioprosthesis structural valve degeneration: a case report

    “Valve-in-valve” technique is an effective method to treat the bioprosthesis structural valve degeneration. In this paper, an 82-year-old male patient with severe aortic valve regurgitation had underwent surgical aortic valve replacement. He had a bioprosthesis structural valve degeneration which caused severe aortic stenosis more than 3 years after surgery. His symptoms of chest distress and short breath were aggravated progressively, and not relieved by conventional treatment. As the deterioration in his unstabled circulation system, an emergency transcatheter aortic valve replacement was conducted for him. The operation was finally successful, the symptoms were relived significantly after operation, and then the follow-up indicated that he had a good recovery.

    Release date:2022-05-24 03:47 Export PDF Favorites Scan
  • Research status of long-term durability in transcatheter aortic valve replacement

    The implantation of bioprosthetic heart valves have increased dramatically due to the aging population and the widespread application of transcatheter aortic valve replacement (TAVR). TAVR is increasingly being used in younger, lower-risk patients with a longer life expectancy, so it is important to overcome structural valve degeneration and ensure long-term TAVR durability. Although the mid-term durability results of the TAVR valve are encouraging, its long-term durability needs to be further explored. This article will mainly introduce the influencing factors of TAVR valve durability, evaluation criteria for structural valve degeneration, clinical research results related to TAVR valve durability, and problems to be solved.

    Release date:2022-05-24 03:47 Export PDF Favorites Scan
  • Transcatheter aortic valve replacement (TAVR) annual report 2023

    Transcatheter aortic valve replacement (TAVR) has seen a surge in clinical research, basic research, and innovative device development both domestically and internationally in the previous 2023. This article aims to review the progress of TAVR in the past year from the perspectives of international, and domestic research development of application. It highlights new clinical and basic research findings both domestically and internationally, the emergence of new devices and technologies, and the development and use of TAVR in China. Finally, it provides an outlook on the trajectory of TAVR development in 2024.

    Release date:2024-04-28 03:40 Export PDF Favorites Scan
  • Development of transcatheter heart valve therapy in the world in 2020

    In 2020, due to the impact of the novel coronavirus epidemic, the development of transcatheter heart valve therapy has been shown to slow down, but there are still many aspects worth noting. The indication of monoclonal antibody after transcatheter aortic valve replacement (TAVR) should be further clarified. Low surgical risk patients were included in TAVR relative indications. Mitraclip G4 was approved by CE. The indication of atrial septal occlusion after mitraclip should be further clarified. The technique of coaptation augmentation is expected to become a new method of mitral valve interventional repair. Tendyne transcatheter mitral valve was approved by European Union. Transcatheter tricuspid valve treatment equipments, TriClip and PASCAL obtained CE mark. TAVR technology is being popularized rapidly in China, and what’s more, balloon dilated valve Sapien 3 and new recyclable repositioning valve system-Venus plus have entered the domestic market. A number of mitral valve therapeutic instruments have appeared one after another, and China's first tricuspid valve lux has completed its FIM research. Finally, with the improvement of devices and technology in the future, interventional therapy of heart valve is expected to benefit more patients.

    Release date:2021-04-25 09:57 Export PDF Favorites Scan
  • The Affecting Factors on Sinus Rhythms Maintenance after Electric Cardioversion for Atrial Fibrillation in Patients after Cardiac Valve Replacement

    Objective To explore the affecting factors on sinus rhythm maintenance after electric cardioversion for patients with atrial fibrillation (Af) after cardiac valve replacement. Methods One hundred fifty two valvular disease patients with Af after cardiac valve replacement were randomized to 2 groups: Amiodarone group and control group (without anti arrhythmic drugs) after cardioversion. Af recurrence was observed during one year follow up. Results (1) No significant difference of Af recurrence betwe...

    Release date:2016-08-30 06:35 Export PDF Favorites Scan
  • Progress and prospect of robotic cardiac surgery

    Minimally invasive cardiac surgeries are the trend in the future. Among them, robotic cardiac surgery is the latest iteration with several key-hole incision, 3-dimentional visualization, and articulated instrumentation of 7 degree of ergonomic freedom for those complex procedures in the heart. In particular, robotic mitral valve surgery, as well as coronary artery bypass grafting, has evolved over the last decade and become the preferred method at certain specialized centers worldwide because of excellent results. Other cardiac procedures are in various stages of evolution. Stepwise innovation of robotic technology will continue to make robotic operations simpler, more efficient, and less invasive, which will encourage more surgeons to take up this technology and extend the benefits of robotic surgery to a larger patient population.

    Release date:2019-09-18 03:45 Export PDF Favorites Scan
  • Minimally Invasive Mitral Valve Replacement Combined with Atrial Fibrillation Radiofrequency Ablation via Right Minithoracotomy

    ObjectiveTo summarize clinical advantages and outcomes of minimally invasive mitral valve replacement (MVR) combined with atrial fibrillation (AF) radiofrequency ablation via right minithoracotomy. MethodsEight patients with mitral valve disease and AF who received surgical therapy in the First Hospital of China Medical University between October 2009 and October 2012 were included in the study. There were 4 males and 4 females with their age of 34-67 (52.4±17.5) years. All the patients underwent minimally invasive MVR combined with AF radiofrequency ablation via right minithoracotomy. Clinical outcomes were summarized. ResultsThere was no in-hospital death or conversion to conventional sternotomy in this group. Two patients received biological valve replacement and 6 patients received mechanical prosthesis. Operation time was 207.9±18.1 minutes, cardiopulmonary bypass time was 81.7±23.9 minutes, and chest drainage amount was 126.7±34.5 ml. AF recurred in 1 patient on the 3rd postoperative day. All the patients were in sinus rhythm at discharge. These patients were followed up for 18.3±7.4 months. During follow-up, 1 patient had AF recurrence. Seven patients were in NYHA class Ⅰ, and 1 patients was in NYHA class Ⅱ. ConclusionMinimally invasive MVR combined with AF radiofrequency ablation via right minithoracotomy can achieve satisfactory clinical results and esthetic appearance, and is a good choice for patients with mitral valve disease and AF.

    Release date: Export PDF Favorites Scan
  • A case of perivalvular leakage and attempt of closure operation after transcatheter aortic valve replacement

    This paper reported a 75-year-old female patient. She was admitted to our hospital for “repeated chest pain, shortness of breath for more than 5 years, and syncope 3 times”. The CT scan of the patient showed severe aortic valve stenosis, bicuspid valve, and severe calcification; then she underwent transcatheter aortic valve replacement in our hospital. After the prosthesis was implanted, there was a significant paravalvular leak. Considering the triangular area formed between the calcified clumps, the valve was not fully dilated. Paravalvular leak closure was performed during the operation, attempted through the valve stent mesh to closuring. A rare incarceration of the transmitter occurred. An attempt was made to pull out the incarcerated transmitter through a pull-up technique, which resulted in the prosthesis prolapse. The patient was eventually transferred to surgery aortic valve replacement.

    Release date:2020-05-26 02:34 Export PDF Favorites Scan
32 pages Previous 1 2 3 ... 32 Next

Format