ObjectiveTo study the feasibility and safety of CT-guided preoperative Hookwire localization of pulmonary nodules in clinical application.MethodsClinical data of 102 patients who were scheduled to undergo surgical treatment for pulmonary nodules from June 2015 to April 2020 in the North Ward of Thoracic Surgery Department of Ruijin Hospital were retrospectively analyzed. There were 38 males and 64 females, aged 23-82 (53.2±12.8) years.ResultsAll 102 patients with pulmonary nodules underwent CT-guided preoperative Hookwire localization successfully, with a localization success rate of 100.0%. The localization time was 27.0 (11-67) min; the number of times to adjust the angle during the positioning process was 6.9 (3-14); the needle depth of the positioning needle was 41.5 (16.3-69.1) mm. A total of 48 (47.1%) patients had a small amount of bleeding in the lung tissue in the positioning area after positioning; 53 (51.9%) patients had a small amount of pneumothorax after positioning; 16 (15.7%) patients were found that the positioning needle completely shedded from the lung tissue in the subsequent surgery. One patient was transferred to open thoracotomy because of extensive dense adhesion in the thorax, and the remaining 101 patients were operated on under thoracoscopy. Postoperative pathology showed that 5 (4.9%) patients were adenocarcinoma in situ, 28 (27.5%) were microinvasive adenocarcinoma, 36 (35.3%) patients were invasive carcinoma and 32 (31.3%) patients were benign lesions. No patients had complications or adverse events related to preoperative positioning.ConclusionPreoperative CT-guided localization of Hookwire intrapulmonary nodules is safe and effective, and can meet the intraoperative localization needs of thoracic surgeons in most clinical situations, and is not inferior to other preoperative localization methods currently used in clinics.
ObjectiveTo systematically evaluate the application effect of CT-guided Hook-wire localization and CT-guided microcoil localization in pulmonary nodules surgery. MethodsThe literatures on the comparison between CT-guided Hook-wire localization and CT-guided microcoil localization for pulmonary nodules were searched in PubMed, EMbase, The Cochrane Library, Web of Science, Wanfang, VIP and CNKI databases from the inception to October 2021. Review Manager (version 5.4) software was used for meta-analysis. The Newcastle-Ottawa Scale (NOS) was used to evaluate the quality of studies.ResultsA total of 10 retrospective cohort studies were included, with 1 117 patients including 473 patients in the CT-guided Hook-wire localization group and 644 patients in the CT-guided microcoil localization group. The quality of the studies was high with NOS scores>6 points. The result of meta-analysis showed that the difference in the localization operation time (MD=0.14, 95%CI −3.43 to 3.71, P=0.940) between the two groups was not statistically significant. However, the localization success rate of the Hook-wire group was superior to the microcoil group (OR=0.35, 95%CI 0.17 to 0.72, P=0.005). In addition, in comparison with Hook-wire localization, the microcoil localization could reduce the dislocation rate (OR=4.33, 95%CI 2.07 to 9.08, P<0.001), the incidence of pneumothorax (OR=1.62, 95%CI 1.12 to 2.33, P=0.010) and pulmonary hemorrhage (OR=1.64, 95%CI 1.07 to 2.51, P=0.020). ConclusionAlthough Hook-wire localization is slightly better than microcoil localization in the aspect of the success rate of pulmonary nodule localization, microcoil localization has an obvious advantage compared with Hook-wire localization in terms of controlling the incidence of dislocation, pneumothorax and pulmonary hemorrhage. Therefore, from a comprehensive perspective, this study believes that CT-guided microcoil localization is a preoperative localization method worthy of further promotion.
ObjectiveTo investigate the clinical value of 3D CT combined with CT-guided Hookwire for localizing small pulmonary nodules in thoracoscopic pulmonary segmentectomy.MethodsFrom December 2017 to February 2019, 39 patients received thoracoscopic pulmonary segmentectomy in our hospital, including 14 males and 25 females with a mean age of 51.33±11.17 years. Before operation, we used Mimics Medical 20.0 to re-establish the anatomy of lung and locate the small pulmonary nodules with Hookwire guided by CT. Based on the position of Hookwire needle, 3D CT images and simulated surgical methods, thoracoscopic pulmonary segmentectomy was performed accurately.ResultsThe surgery was successfully completed in 39 patients without a transfer to open procedure. The mean operation time, mean intraoperative blood loss, mean postoperative hospital stay, mean thoracic tube drainage time were 148.97±28.56 min, 27.95±17.57 mL, 6.95±1.68 d, 4.21±1.95 d, respectively. Postoperative complications occurred in 5 patients (12.82%), including atrial fibrillation in 1, pulmonary infection in 1, chylothorax in 1, intrathoracic hemorrhage in 1 and pneumothorax in 1. All actual surgical margins were larger than 3.0 cm.ConclusionThe application of preoperative 3D CT combined with CT-guided Hookwire to localize small pulmonary nodules is helpful for accurate anatomical segmental resection of the lung, making the operation safe .
Objective To observe the effectiveness of skin graft combined with thorax wire fastening for repairing postoperative coloboma after resection of chest back giant nevus. Methods Between June 2007 and October 2010, 17 cases of chest back giant nevus were treated. There were 7 males and 10 females, aged from 3 years and 6 months to 15 years(mean, 8 years). The size of giant nevus was 20 cm × 12 cm to 60 cm × 50 cm. Two cases of them were ever treated by laser, while the others were never treated. The check before operation showed ulcer of the skin and effusion in 2 cases, hard skin in 3 cases, hair growth in 7 cases, and normal in 5 cases. Five cases had serious itch. After giant nevus was cut off, thorax wire was fastened to reduce the wound area, and then the intermediate spl it thickness skin graft of thigh was used to repair the wound. Comprehensive anti-scar treatment was given postoperatively. Results The wound size was (2 110.74 ± 725.69) cm2 after resection of giant nevus, and was (1 624.94 ± 560.57) cm2 after thorax wire fastening, showing significant difference (t=9.006, P=0.001). All the grafting skin survived; the incision and wound at donor site healed by first intention. The patients were followed up 6 months to 2 years (mean, 13 months). No scar prol iferation or contracture occurred. The skin color and elasticity were similar to the normal skin; the nipple, navel, and other local apparatus were not shifted after operation. Conclusion It can reduce donor site of skin and postoperative scar, and achieve satisfactory appearance to cover the wound by skin graft combined with thorax wire fastening after chest back giant nevus was cut off .
ObjectiveTo investigate the effectiveness of Kirschner wire fixation in scapholunate joint, capitolunate joint, and lunotriquetral joint combined with bone anchor repair for the treatment of acute perilunate injury. MethodsBetween January 2007 and January 2012, 35 cases of acute perilunate injury were treated. There were 30 males and 5 females with an average age of 45.5 years (range, 32-56 years). Fractures were caused by falling from height in 18 cases, by traffic accident in 11 cases, and by fall injury in 4 cases. The time from injury to operation was 2-6 days (mean, 3.4 days). There were 23 cases of trans-scaphoid perilunate dislocation, 10 cases of perilunate dislocation, and 2 cases of trans-triangular perilunate dislocation. Associated injuries included median nerve injury in 6 cases, radius styloid fracture in 8 cases, ulnar styloid fracture in 2 cases, and distal tibial fracture in 1 case. All the patients were treated by open reduction, Herbert screw fixation of scaphoid fractures, and Kirschner wire fixation in scapholunate joint, capitolunate joint, and lunotriquetral joint, and the intercarpal ligaments were repaired by Mitek bone anchor. ResultsSuperficial wound infection occurred in 2 cases, and primary healing of incision obtained in others. Thirty-five patients were followed up 12-35 months (mean, 18 months). X-ray films showed fracture union in 21 cases of scaphoid fractures, and bone nonunion in 2 cases of scaphoid fractures. During the follow-up period, there was no avascular necrosis of scaphoid or lunate. At last follow-up, the scapholunate angle, radiolunate angle, and wrist range of motion (ROM) in extension had no significant difference between affected and unaffected sides (P > 0.05). The wrist ROM in flexion and grip strength of affected side were not up to the levels of unaffected side (P < 0.05). According to the modified Mayo wrist scoring system, the score was 79.9±10.7, which were excellent in 8 cases, good in 17 cases, fair in 7 cases, and poor in 3 cases, and the excellent and good rate was 71.4%. The disability of arm-shoulder-hand (DASH) questionnaires score was 21±10. Traumatic osteoarthritis was observed in 2 cases. ConclusionKirschner wire fixation in scapholunate joint, capitolunate joint, and lunotriquetral joint combined with bone anchor repair for the treatment of acute perilunate injury can get early stability of the carpal joint, favorable intercarpal ligament repair, and good recovery of wrist joint function.
ObjectiveTo compare the effectiveness of improved and traditional Kirschner wire tension band fixation in treatment of type C patellar fractures.MethodsBetween January 2017 and January 2019, 26 patients with type C patellar fractures were treated with improved Kirschner wire tension band fixation (group A), and 24 patients were treated with traditional Kirschner wire tension band fixation (group B). There was no significant difference in gender, age, injury cause, disease duration, and side and type of fracture between 2 groups (P>0.05). The operation time, intraoperative blood loss, the visual analogue scale (VAS) scores at 1 and 3 days after operation, the fracture healing time, and the occurrence of complications (skin irritation of Kirschner wires, failure of internal fixation, fracture reduction loss) were recorded, and the knee function was evaluated by Lysholm scoring standard in 2 groups.ResultsThe operation time in group A was significantly less than that in group B (t=−4.742, P=0.000). There was no significant difference in the intraoperative blood loss and VAS scores at 1 and 3 days after operation between 2 groups (P>0.05). All incisions healed by first intention. All patients were followed up 8-15 months, with an average of 11 months. The fracture healing time was (3.3±0.6) months in group A and (3.2±0.6) months in group B, showing no significant difference (t=0.589, P=0.559). At last follow-up, the knee joint function was evaluated according to Lysholm scoring standard. And there were 15 cases of excellent, 8 cases of good, and 3 cases of fair, with an excellent and good rate of 88.5% in group A; there were 8 cases of excellent, 7 cases of good, 7 cases of fair, and 2 cases of poor, with an excellent and good rate was 62.5%. The difference between 2 groups was significant (Z=2.828, P=0.005). The internal fixators were removed after the fracture healed in 2 groups. At last follow-up, no skin irritation of Kirschner wires occurred in group A, but 3 cases in group B. X-ray films reexamination showed that 5 cases of internal fixation failure and no fracture reduction loss were found in group A, while 9 cases of internal fixation failure and 1 case of fracture reduction loss in group B. The incidence of complications in group A was 19.2% (5/26), which was significantly lower than that in group B (54.2%, 13/24) (χ2=6.611, P=0.010).ConclusionCompared with the traditional Kirschner wire tension band fixation, the improved Kirschner wire tension band fixation in treatment of type C patellar fracture can shorten the operation time, reduce the incidence of complications, and benefit the functional recovery of knee joint.
Objective To compare the biomechanical stability of Kirschner wire and tension band wiring, reconstruction plate combined with tension band wiring, and olecranon anatomical plate in fixing proximal ulna combined with olecranon fracture, so as to provide the theoretical evidence for clinical selection of internal fixation. Methods Eight specimens of elbow joints and ligaments were taken from eight fresh male adult cadaveric elbows (aged 26-43 years, mean 34.8 years) donated voluntarily. The model of proximal ulna combined with olecranon fracture was made by an osteotomy in each specimen. Fracture end was fixed successively by Kirschner wire and tension band wiring (group A), reconstruction plate combined with tension band wiring (group B), and olecranon anatomical plate (group C), respectively. The biomechanical test was performed for monopodium compression experiments, and load-displacement curves were obtained. The stability of the fixation was evaluated according to the load value when the compression displacement of fracture segment was 2 mm. Results No Kirschner wire withdrawal, broken plate and screw, loosening and specimens destruction were observed. The load-displacement curves of 3 groups showed that the displacement increased gradually with increasing load, while the curve slope of groups B and C was significantly higher than that of group A. When the compression displacement was 2 mm, the load values of groups A, B, and C were (218.6 ± 66.9), (560.3 ± 116.1), and (577.2 ± 137.6) N, respectively; the load values of groups B and C were significantly higher than that of group A (P lt; 0.05), but no significant difference was observed between groups B and C (t=0.305, P=0.763). Conclusion The proximal ulna combined with olecranon fracture is unstable. Reconstruction plate combined with tension band wiring and olecranon anatomical plate can meet the requirement of fracture fixation, so they are favorable options for proximal ulna combined with olecranon fracture. Kirschner wire and tension band wiring is not a stable fixation, therefore, it should not be only used for proximal ulna combined with olecranon fracture.
Objective To investigate the effectiveness of arthroscopy-assisted combined fixation of Kirschner wire and external fixator for treating extreme distal radial fractures. Methods Between January 2014 and May 2016, 21 patients who suffered from extreme distal radial fractures were treated by arthroscopy-assisted combined fixation of Kirschner wire and external fixator. There were 14 males and 7 females with an age of 32-57 years (mean, 42.3 years). The causes of injury included falling in 13 cases and traffic accident in 8 cases. The fracture type included 8 cases of type 23C1, 9 cases of type 23C2, and 4 cases of type 23C3 according to AO/OTA classification. The time from injury to operation was 3-7 days (mean, 4.4 days). The Mayo score and disability of arm, shoulder, and hand (DASH) score were used to assess the pain and function of the wrist joint. Results There was no needle red swelling, tendon irritation, or orther early complications. All the patients were followed up 10-35 months (mean, 18.3 months). The fracture healing time was 9-13 weeks (mean, 10.6 weeks). At last follow-up, the Mayo score was 87-94 (mean, 90.9); and 17 cases were excellent and 4 were good. The DASH score was 7-13 (mean, 10.6). Conclusion Arthroscopy-assisted combined fixation of Kirschner wire and external fixator for treating extreme distal radial fractures has the advantages of firm fixation, early functional exercise, less postoperative complications, and good functional recovery of wrist joint.
ObjectiveTo compare the clinical efficacy of left ventricular wire pacing with traditional right ventricular lead pacing in transcatheter aortic valve replacement. MethodsPerioperative data of patients undergoing transcatheter aortic valve replacement at the Second Hospital of Hebei Medical University from January 2022 to June 2023 were collected. Patients were divided into a left ventricular wire pacing group and a right ventricular lead pacing group based on the pacing method during the procedure, and the clinical data of the two groups were compared and analyzed. ResultsA total of 102 patients were included, with 35 patients in the left ventricular wire pacing group [20 males and 15 females, age (69.2±3.1) years] and 67 patients in the right ventricular lead pacing group [37 males and 30 females, age (70.2±3.7) years]. The hemodynamic characteristics of both groups (peak flow velocity, peak transvalve pressure difference, left ventricular ejection fraction) showed significant improvement post-operation compared to pre-operation (P<0.05). There was no statistically significant difference between the two groups in terms of pacing success rate and surgical complications (P>0.05). Compared to the right ventricular lead pacing group, the left ventricular wire pacing group had shorter operation time [(76.3±17.2) min vs. (86.1±15.3) min, P=0.004] and X-ray exposure time [(18.2±6.1) min vs. (26.2±4.3) min, P<0.001], and lower total hospitalization cost [(213±28) thousand yuan vs. (262±25) thousand yuan, P<0.001]. ConclusionThe safety and reliability of left ventricular wire pacing in transcatheter aortic valve replacement are similar to those of traditional right ventricular lead pacing. Moreover, it can significantly reduce the operation and X-ray exposure time and decrease the total clinical hospitalization cost, making it a viable alternative to traditional right ventricular lead pacing.
Wireless power transfer (WPT) is a new power transmission way, which can be widely used in electric vehicles and other fields. Its electromagnetic environment must be analyzed to ensure safe application. A low-power wireless power transfer system experimental platform was built, with 25 W receiving power and 47 kHz resonant frequency, which was used to carry out animal experiments. Treatment mice were exposed to environment of wireless power transfer system for 5 h a day and 6 days as one cycle. At the end of every cycle, learning memory behavior of mice were detected in T-shaped maze. The exposure experiment lasted for 12 weeks. Finally, immune parameters, sex hormones and part of organ physiological structure were detected. The results are as follows: as exposure time increased, memory behavior of mice did not change obviously with no statistical difference in sex hormone either (P > 0.05), the concentration of immune factors including tumor necrosis factor-α (TNF-α), interleukin 6 (IL-6) and interleukin-1 beta (IL-1β) significantly increased (P < 0.05), and the structure of some organs showed some changes. The experimental results show that the environment of the wireless power transfer system has no effect on the memory behavior of mice, and has some effect on physiological properties of mice.