west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "定位" 129 results
  • Expression of Krüppel like factor 8 in breast cancer and its clinical significances

    ObjectiveTo detect the expression of Krüppel like factor 8 (KLF8) in breast cancer tissues and cells and to explore the clinical significance of KLF8.Methods① The Oncomine database was used to analyze the differential expression of KLF8 mRNA in the breast cancer tissues. The Kaplan-Meier Plotter database was used to analyze the relationship between KLF8 mRNA expression and prognosis (relapse free survival, overall survival, post-progression survival, and distant metastasis-free survival) of patients with breast cancer. ② The quantitative real-time PCR (qRT-PCR) and Western blot were used to detect the KLF8 expression levels in the 16 clinical patients with breast cancer and 7 breast cancer cell lines (MDA-MB-231, MCF-12A, Hs-578T, MCF-7, BT-474, MDA-MB-453, ZR-75-30) and normal breast epithelial cell lines MCF-10A, and the immunofluorescence was used to further detect the localization of KLF8 expression in the 2 breast cancer cell lines with higher KLF8 expression level. ③ The immunohistochemistry was used to detect the expression of KLF8 protein in 135 cases of breast cancer tissue microarrays, and the relationships between KLF8 protein expression and clinicopathologic characteristics or overall survival were analyzed.Results① The Oncomine database showed that KLF8 mRNA expression in the breast cancer tissues was higher than that in the normal breast tissues (P<0.001). The median KLF8 mRNA expression level was taken as the cut-off point for high or low KLF8 expression. The results of Kaplan-Meier Plotter data analysis showed that the prognosis (relapse free survival, overall survival, postprogression survival, and distant metastasis-free survival) of patients with low KLF8 mRNA expression were better than those of patients with high KLF8 mRNA expression (P<0.05). ② The results of qRT-PCR and Western blot all showed that the KLF8 mRNA and protein expression levels in the breast cancer tissues were higher than those in the adjacent normal tissues (P=0.002, P<0.001). In addition, the Western blot results showed that the expression of KLF8 protein in the 7 breast cancer cell lines was higher than that in the normal breast epithelial cell lines MCF-10A respectively, and KLF8 protein mainly expressed in the cytoplasm of breast cancer cells and highly expressed in the nuclear of a few cells. ③ There were 63 cases of high KLF8 expression and 72 cases of low KLF8 expression by the immunohistochemical analysis of 135 patients with breast cancer tissue microarray (the H-score of the immunohistochemical test results was 75 as the cut-off point, H-score >75 was the high KLF8 expression and H-score ≤75 was the low KLF8 expression), the differences of statuses of estrogen receptor (ER) and progesterone receptor (PR) between the patient with high KLF8 expression and low KLF8 expression were significant (P<0.05). The Kaplan-Meier survival curve analysis showed that the prognosis of patients with high KLF8 expression was worse than that of patients with low KLF8 expression (P=0.002). The univariate analysis showed that the TNM stage, statuses of ER and PR, and KLF8 expression were related to the prognosis of patients with breast cancer (P<0.05), further multivariate Cox proportional hazards regression analysis indicated that the later stage of TNM and high KLF8 expression were the independent risk factors (P<0.05).ConclusionsThe results of this study suggest that KLF8 highly expresses in both breast cancer tissues and breast cancer cells, which is related to the statuses of ER and PR and prognosis of patients with breast cancer. KLF8 might be involved in the progression of breast cancer as an oncogenic gene, or it might provide a new direction for prognosis judgment and molecular targeted therapy of breast cancer.

    Release date:2021-11-05 05:51 Export PDF Favorites Scan
  • Application of CT-guided microcoil localization in single utility port video-assisted thoracoscopic surgery for small pulmonary nodules (diameter≤15 mm): A retrospective cohort study

    ObjectiveTo explore the application value of CT-guided microcoil localization in pulmonary nodule (diameter≤15 mm) surgery.MethodsThe clinical data of 175 patients with pulmonary nodules who underwent single utility port video-assisted thoracoscopic surgery at Nanjing Drum Tower Hospital from August 2018 to December 2019 were retrospectively analyzed. According to whether CT-guided coil localization was performed before operation, they were divided into a locating group and a non-locating group. There were 84 patients (34 males, 50 females, aged 57.8±8.8 years) in the locating group and 91 patients (46 males, 45 females, aged 57.6±10.8 years) in the non-locating group. The localization success rate, localization time, incidence of complications, surgical and postoperative conditions were analyzed between the two groups.ResultsAll 84 patients in the locating group were successfully located, and localization time was 19.0±3.6 minutes. Among them, 19 (22.6%) patients had a small pneumothorax, 4 (4.8%) pulmonary hemorrhage and 2 (2.4%) coil shift; 6 (7.1%) patients had mild pain, 3 (3.6%) moderate pain and 1 (1.2%) severe pain. Sex (P=0.181), age (P=0.673), nodule location (P=0.167), nature of lesion (P=0.244), rate of conversion to thoracotomy (P=0.414), rate of disposable resection of nodules (P=0.251) and postoperative hospital stay (P=0.207) were similar between the two groups. There were significant differences in nodule size (P<0.001), nature of nodule (P<0.001), the shortest distance from nodule to pleura (P<0.001), operation time (P<0.001), lung volume by wedge resection (P=0.031), number of staplers (P<0.001) and total hospitalization costs (P<0.001) between the two groups.ConclusionCT-guided microcoil localization has the characteristics of high success rate, and is simple, practicable, effective, safe and minimally invasive. Preoperative CT-guided microcoil localization has important clinical application value for small pulmonary nodules, especially those with small size, deep location and less solid components. It can effectively shorten the operation time, reduce surgical trauma and lower hospitalization costs, which is a preoperative localization technique worthy of popularization.

    Release date:2022-01-21 01:31 Export PDF Favorites Scan
  • CHOLECYSTECTOMY BY MINI INCISION (REPORT OF 840 CASES)

    目的 总结840例小切口胆囊切除术的经验体会。方法 我院应用新器械行小切口胆囊切除术840例,男302例,女538例,年龄16~64岁; 胆囊结石832例,胆囊息肉8例。其手术指征与大切口胆囊切除术相同。术中应用小切口自动伸开架、深部送结器、小切口带灯拉钩、缝合胆囊肝床之外科扣锁钳、肝脏直角灯钩以及为防止在小切口内手术时遗失纱布而特制的气囊纱布; 同时,确保手术能在小切口内完成,术前进行了周密检查以排除肝、胆、胃之肿瘤,并于术前行动态胆囊底B超定位检查,以确定小切口之位置和了解手术难易。结果 840例中行择期手术737例,急诊手术103例; 手术历时平均30分钟; 住院时间3~4天。术后全部患者均获随访,其满意度为98.5%(827/840)。因照明障碍误伤右肝管1例,因胆囊颈结石嵌顿误伤胆总管1例。结论 应用小切口及自制手术器械行胆囊切除术,避免了LC及传统开腹术的一些弊端,效果确切,便于患者接受。

    Release date:2016-09-08 01:59 Export PDF Favorites Scan
  • EXPERIMENTAL STUDY OF CERVICAL PEDICLE SCREW LOCATOR SYSTEM

    Objective To develop a high-accuracy, better-safety and low-cost cervical pedicle locator system for guiding cervical pedicle screw placement. Methods Cervical pedicle screw locator system was made of stainless steel. Ten cervical specimens from voluntary donation were divided into two groups according to compatibil ity design: control group inwhich 60 screws were planted into C2-7 by free hand; and experimental group in which 60 screws were planted into C2-7 under the guidance of three-dimensional locator system. The condition of screw insertion was observed and the accuracy was evaluated by the integrity of pedicle walls. Results In the control group, 32 screws (53.33%) were placed inside the pedicles and 28 (46.67%) were outside; 9 screws (15.00%) led to nerve root injury, 5 screws (8.33%) caused vertebral artery injury and no spinal cord injury occurred; and the qual ification ratio of screw insertion was 76.67% (excellent 32, fair 14, poor 14). While in the experimental group, 54 screws (90.00%) were placed inside the pedicles and 6 (10.00%) were outside; 1 screw (1.67%) caused vertebral artery injury and no nerve root injury and spinal cord injury occurred; and the qual ification ratio of screw insertion was 98.33% (excellent 54, fair 5, poor 1). There was significant difference between the two groups (P lt; 0.05). Conclusion Cervical pedicle screw locator system has the advantages of easy manipulation, high accuracy of screw placement and low cost. With further study, it can be appl ied to the cl inical.

    Release date:2016-09-01 09:05 Export PDF Favorites Scan
  • Research on pulmonary nodule recognition algorithm based on micro-variation amplification

    Objective To develop an innovative recognition algorithm that aids physicians in the identification of pulmonary nodules. MethodsPatients with pulmonary nodules who underwent thoracoscopic surgery at the Department of Thoracic Surgery, Affiliated Drum Tower Hospital of Nanjing University Medical School in December 2023, were enrolled in the study. Chest surface exploration data were collected at a rate of 60 frames per second and a resolution of 1 920×1 080. Frame images were saved at regular intervals for subsequent block processing. An algorithm database for lung nodule recognition was developed using the collected data. ResultsA total of 16 patients were enrolled, including 9 males and 7 females, with an average age of (54.9±14.9) years. In the optimized multi-topology convolutional network model, the test results demonstrated an accuracy rate of 94.39% for recognition tasks. Furthermore, the integration of micro-variation amplification technology into the convolutional network model enhanced the accuracy of lung nodule identification to 96.90%. A comprehensive evaluation of the performance of these two models yielded an overall recognition accuracy of 95.59%. Based on these findings, we conclude that the proposed network model is well-suited for the task of lung nodule recognition, with the convolutional network incorporating micro-variation amplification technology exhibiting superior accuracy. Conclusion Compared to traditional methods, our proposed technique significantly enhances the accuracy of lung nodule identification and localization, aiding surgeons in locating lung nodules during thoracoscopic surgery.

    Release date:2025-02-28 06:45 Export PDF Favorites Scan
  • Localized Biopsy of Nonpalpable Breast Lesions and It’s Role in Early Diagnosis and Treatment of Breast Cancer

    【Abstract】ObjectiveTo evaluate the localized biopsy of nonpalpable breast lesions (NPBLs) and its role in the early diagnosis and treatment of breast cancer. MethodsOne hundred and fifty-eight NPBLs from a series of 141 women detected by mammography were resected with wire localization technique. ResultsForty-two lesions (26.6%, 42/158) in 42 patients were diagnosed with malignant result, including 12(28.6%) patients with stage 0 breast cancer, 24(57.1%) with stageⅠ, 2(4.8%) with stage Ⅱ and 4(9.5%) with stage Ⅲ disease according to American Joint Committee on Cancer (AJCC) staging system(the 6th edition). The contralateral axillary lymph nodes metastasis were found in only one (2.4%) patient with stage Ⅲ disease and the other fortyone patients remained free of recurrent disease at a median follow-up of 31 months.ConclusionThe results showed that the most nonpalpable breast cancers detected by mammography were earlystage breast cancers and had good prognosis. The NPBLs should get a localized biopsy in order to facilitate the early diagnosis and treatment of nonpalpable breast cancers.

    Release date:2016-09-08 11:54 Export PDF Favorites Scan
  • Safety evalution of laparoscopic cholecystectomy guided by gallbladder ampulla localization on an imaginary clock for cholecystitis

    ObjectiveTo explore technical essentials and safety of laparoscopic cholecystectomy (LC) guided by gallbladder ampulla localization on an imaginary clock for cholecystitis.MethodsA retrospective study of 8 707 continuous patients with mild cholecystitis who underwent LC from July 1998 to February 2018 at a single institution was conducted. Among them, 3 168 patients were treated by the traditional LC from July 1998 to February 2007 (a traditional LC group), 5 539 patients were treated by the LC with the guidance of the gallbladder ampulla localization on an imaginary clock from March 2007 to February 2018 (a gallbladder ampulla localization group). The conversion to open surgery, bile duct injury, return to the operating room due to postoperative massive abdominal bleeding, bile leakage without bile duct injury, operative time, intraoperative blood loss, and postoperative hospital stays were compared between the traditional LC group and the gallbladder ampulla localization group.ResultsThere were no significant differences in the gender, age, course of disease, and type of cholecystitis between these two groups (P>0.050). The rates of conversion to open surgery, bile duct injury, return to the operating room due to postoperative massive abdominal bleeding, bile leakage without bile duct injury and the operative time, intraoperative blood loss and postoperative hospital stays in the traditional LC group were 3.00% (95/3 168), 0.13% (4/3 168), 0.09% (3/3 168), 0.03% (1/3 168), (43.6±12.6) min, (18.7±3.3) mL, (3.6±2.7) d, respectively, which in the gallbladder ampulla localization group were 0 (0/5 539), 0 (0/5 539), 0 (0/5 539), 0 (0/5 539), (32.2±10.5) min, (12.4±3.5) mL, (3.5±2.8) d, respectively. The differences of conversion to open surgery, bile duct injury, return to the operating room due to postoperative massive abdominal bleeding rates, and the operative time and intraoperative blood loss were statistically significant between these two groups (P<0.050). The differences of the bile leakage without bile duct injury rate and postoperative hospital stays were not statistically significant between the two groups (P>0.050).ConclusionThis study shows that gallbladder ampulla localization on an imaginary clock is useful for ductal identification so as to reduce bile duct injury and improve safety of LC in case of no conversion to open surgery.

    Release date:2019-06-26 03:20 Export PDF Favorites Scan
  • Application of 3D Digital Lung Software in Preoperative Planning of Patients with Mul-tiple Pulmonary Nodules and Poor Pulmonary Function

    ObjectiveTo assess the feasibility of 3D digital lung software used in preoperative planning of patients with multiple pulmonary nodules and poor pulmonary function. MethodsFive patients with multiple pulmonary nodules in the left lung, meanwhile with a history of single lung lobectomy in the right lung were included in our hospital between June and December 2015. There were 4 males and 1 female at an average age of 50.4±2.6 years. A 320-slice volumetric CT scanner was used to the CT angiography (CTA) of the pulmonary artery. The data of CT images were imported into the 3D digital lung software that was researched and developed by Xiamen QiangBen Science and Technology Company. The 3D reconstruction of digital virtual lung was completed by this software based on those data. At the same time the soft-ware completed the automatic segmentation of the lung based on the pulmonary artery system and the 3D reconstruction of the pulmonary nodules. The 3D digital lung software calculated the volume proportion of the intended removal (segm-ental lesions) to the whole lung, estimated the effect of surgery on forced expired volume in one second (FEV1), and the patient's tolerance ability to surgery. After the preoperative planning, the patients received multiple pulmonary segmental/subsegmental resection under the general anesthesia by video-assisted thoracoscopic surgery (VATS). ResultsThe 3d reconstruction of the pulmonary arteries reached 5 levels in 5 patients. And the software automatically identified out the lung segment/subsegment to show the lung nodules of lung segment/subsegment. The preselection lung volume of 5 patients accounted for 14.00%-27.00% of total lung volume. The software estimated FEV1 as 1.16-1.46 L which can tolerate the operation. The 5 patients were successfully performed surgery of multiple pulmonary segmental/subsegmental resection under the general anesthesia by VATS. The software located lung nodules from the resection of pulmonary segments during operation immediately. Then we sent them to the rapid pathological examination for diagnosis. After operation, the patients recovered well, and had no respiratory insufficiency. Hospitalization day was 4 days. ConclusionThe 3D digital pulmonary software can not only automatically identify the pulmonary segments, precisely position the pulmonary nodule, show the relationship among the target pulmonary segments artery, vein, bronchus and the surroun-ding artery, vein, and bronchus, but also calculate the volume of the pulmonary segments, estimate the impact of the pulmonary segmentectomy on the FEV1. It is useful for precise evaluation of the tolerant capacity of multiple pulmonary nodules in patients with unstaged multiple pulmonary segments.

    Release date:2016-11-04 06:36 Export PDF Favorites Scan
  • Clinical application of 3D precise localization based on anatomical markers in the treatment of pulmonary nodules during thoracoscopic surgery

    ObjectiveTo explore the safety and feasibility of 3D precise localization based on anatomical markers in the treatment of pulmonary nodules during video-assisted thoracoscopic surgery (VATS).MethodsFrom June 2019 to April 2015, 27 patients with pulmonary nodules underwent VATS in our Hospital were collected in the study, including 3 males and 24 females aged 51.8±13.7 years. The surgical data were retrospectively reviewed and analyzed, such as localization time, localization accuracy rate, pathological results, complication rate and postoperative hospital stay.ResultsA total of 28 pulmonary nodules were localized via this method. All patients received surgery successfully. No mortality or major morbidity occurred. The general mean localization time was 17.6±5.8 min, with an accuracy of 96.4%. The mean diameter of pulmonary nodules was 14.0±8.0 mm with a mean distance from visceral pleura of 6.5±5.4 mm. There was no localization related complication. The mean postoperative hospital stay was 6.7±4.3 d. The routine pathological result showed that 78.6% of the pulmonary nodules were adenocarcinoma.Conclusion3D precise localization based on anatomical markers in the treatment of pulmonary nodules during thoracoscopic surgery is accurate, safe, effective, economical and practical, and it is easy to master with a short learning curve.

    Release date: Export PDF Favorites Scan
  • Location and segmentation method of optic disc in fundus images based on deep learning

    ObjectiveTo observe and analyze the accuracy of the optic disc positioning and segmentation method of fundus images based on deep learning.MethodsThe model training strategies were training and evaluating deep learning-based optic disc positioning and segmentation methods on the ORIGA dataset. A deep convolutional neural network (CNN) was built on the Caffe framework of deep learning. A sliding window was used to cut the original image of the ORIGA data set into many small pieces of pictures, and the deep CNN was used to determine whether each small piece of picture contained the complete disc structure, so as to find the area of the disc. In order to avoid the influence of blood vessels on the segmentation of the optic disc, the blood vessels in the optic disc area were removed before segmentation of the optic disc boundary. A deep network of optic disc segmentation based on image pixel classification was used to realize the segmentation of the optic disc of fundus images. The accuracy of the optic disc positioning and segmentation method was calculated based on deep learning of fundus images. Positioning accuracy=T/N, T represented the number of fundus images with correct optic disc positioning, and N represented the total number of fundus images used for positioning. The overlap error was used to compare the difference between the segmentation result of the optic disc and the actual boundary of the optic disc.ResultsOn the dataset from ORIGA, the accuracy of the optic disc localization can reach 99.6%, the average overlap error of optic disc segmentation was 7.1%. The calculation errors of the average cup-to-disk ratio for glaucoma images and normal images were 0.066 and 0.049, respectively. Disc segmentation of each image took an average of 10 ms.ConclusionThe algorithm can locate the disc area quickly and accurately, and can also segment the disc boundary more accurately.

    Release date:2020-09-22 04:09 Export PDF Favorites Scan
13 pages Previous 1 2 3 ... 13 Next

Format

Content