west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Wear" 21 results
  • Research on performance optimization method of human-machine physical interaction system considering exoskeleton wearing comfort

    In order to improve the wearing comfort and bearing effectiveness of the exoskeleton, based on the prototype and working mechanism analysis of a relaxation wearable system for knee exoskeleton robot, the static optimization synthesis and its method are studied. Firstly, based on the construction of the virtual prototype model of the system, a comprehensive wearable comfort evaluation index considering the factors such as stress, deformation and the proportion of stress nodes was constructed. Secondly, based on the static simulation and evaluation index of system virtual prototype, multi-objective genetic optimization and local optimization synthesis of armor layer topology were carried out. Finally, the model reconstruction simulation data confirmed that the system had good wearing comfort. Our study provides a theoretical basis for the bearing performance and prototype construction of the subsequent wearable system.

    Release date:2023-02-24 06:14 Export PDF Favorites Scan
  • Application status and future trend analysis of wearable devices in the field of clinical nursing

    Wearable devices, as an important component of digital health, are gradually penetrating into the clinical nursing field. This paper explores the current applications of wearable devices in the field of clinical nursing, with a focus on their significant roles in real-time monitoring of physiological parameters, disease management, functional rehabilitation exercises. Additionally, it analyzes the challenges these devices face, such as the need for standardized development, data security and privacy protection, and cost-benefit analysis. This paper also proposes measures to address these challenges, including enhancing policy formulation, promoting standardization, and fostering technological innovation, with the aim of providing valuable insights for the advancement of high-quality clinical nursing practices.

    Release date:2024-11-27 02:31 Export PDF Favorites Scan
  • EXPRESSION OF CASPASE-3 AND APOPTOSIS IN INTERFACE MEMBRANES OF ASEPTICALLY-LOOSE TOTAL HIP REPLACEMENT

    Objective To observe expression of Caspase-3 and apoptosis around the prosthesis and explore the relationship of the expression and the apoptosis with the periimplant osteolysis. Methods From April 2001 to August 2006, 16 patients (10 males, 6 females) underwent the revision total hip arthroplasty surgery, who had the primary total hip arthroplasty at the ages of 45-67 years and had the revision total hip arthroplasty at the ages of 55-78 years, with the implantation duration of 7-13 years. According to their preoperative X-ray films andthe findings during the operation, the patients were divided into two groups: theloose/osteolytic group (n=8) and the loose/non-osteolytic group (n=8). The interface tissues were obtained from the peri-implant region in the patients. The synovial samples were taken from another 6 patients (2 males, 4 females; age, 54-68years; illness course, 9-15 years), who underwent the primary total hip arthroplasty for osteoarthritis. These 6 patients were used as controls. The tissues were prepared for the immunohistochemical assays to determine the expression of Caspase-3. The TUNEL assays were performed to quantify the apoptotic cells. The quantitative analysis on the positive cells and the correlation with the presence of the particulate wear debris and the severity of osteolysis were also performed. Results The level of the expression for Caspase-3 and the apoptosis index inthe loose/osteolytic group were significantly increased when compared with those in the loose/non-osteolytic group and the control group (P<0.01). The polyethylene particles were surrounded by more positive cells than the metal particles. The positive cells were present at a higher level in the tissue sections where the high-wear status was present when compared with the areas where the low-wear status was present (P<0.05). Conclusion There is a statistical correlation of the Caspase-3 expression to the apoptosis index and to the presence of the particulate wear debris and the severity of osteolysis, which may be one of the key points for the bone reconstruction inhibition and the bone resorption at the boneimplant interface under the stimulation of the wear debris. The apoptosis is involved in the pathogenesis of the aseptic loosening, which is closely related to the signal transportation of Caspase-3.

    Release date:2016-09-01 09:23 Export PDF Favorites Scan
  • Development of intelligent monitoring system based on Internet of Things and wearable technology and exploration of its clinical application mode

    Wearable monitoring, which has the advantages of continuous monitoring for a long time with low physiological and psychological load, represents a future development direction of monitoring technology. Based on wearable physiological monitoring technology, combined with Internet of Things (IoT) and artificial intelligence technology, this paper has developed an intelligent monitoring system, including wearable hardware, ward Internet of Things platform, continuous physiological data analysis algorithm and software. We explored the clinical value of continuous physiological data using this system through a lot of clinical practices. And four value points were given, namely, real-time monitoring, disease assessment, prediction and early warning, and rehabilitation training. Depending on the real clinical environment, we explored the mode of applying wearable technology in general ward monitoring, cardiopulmonary rehabilitation, and integrated monitoring inside and outside the hospital. The research results show that this monitoring system can be effectively used for monitoring of patients in hospital, evaluation and training of patients’ cardiopulmonary function, and management of patients outside hospital.

    Release date:2023-12-21 03:53 Export PDF Favorites Scan
  • Experimental study of the response of articular cartilage surface roughness to load

    Cartilage surface fibrosis is an early sign of osteoarthritis and cartilage surface damage is closely related to load. The purpose of this study was to study the relationship between cartilage surface roughness and load. By applying impact, compression and fatigue loads on fresh porcine articular cartilage, the rough value of cartilage surface was measured at an interval of 10 min each time and the change rule of roughness before and after loading was obtained. It was found that the load increased the roughness of cartilage surface and the increased value was related to the load size. The time of roughness returning to the initial condition was related to the load type and the load size. The impact load had the greatest influence on the roughness of cartilage surface, followed by the severe fatigue load, compression load and mild fatigue load. This article provides reference data for revealing the pathogenesis of early osteoarthritis and preventing and treating articular cartilage diseases.

    Release date:2022-06-28 04:35 Export PDF Favorites Scan
  • Research progress on the application of novel sensing technologies for sleep-related breathing disorder monitoring at home

    Sleep-related breathing disorder (SRBD) is a sleep disease with high incidence and many complications. However, patients are often unaware of their sickness. Therefore, SRBD harms health seriously. At present, home SRBD monitoring equipment is a popular research topic to help people get aware of their health conditions. This article fully compares recent state-of-art research results about home SRBD monitors to clarify the advantages and limitations of various sensing techniques. Furthermore, the direction of future research and commercialization is pointed out. According to the system design, novel home SRBD monitors can be divided into two types: wearable and unconstrained. The two types of monitors have their own advantages and disadvantages. The wearable devices are simple and portable, but they are not comfortable and durable enough. Meanwhile, the unconstrained devices are more unobtrusive and comfortable, but the supporting algorithms are complex to develop. At present, researches are mainly focused on system design and performance evaluation, while high performance algorithm and large-scale clinical trial need further research. This article can help researchers understand state-of-art research progresses on SRBD monitoring quickly and comprehensively and inspire their research and innovation ideas. Additionally, this article also summarizes the existing commercial sleep respiratory monitors, so as to promote the commercialization of novel home SRBD monitors that are still under research.

    Release date:2022-10-25 01:09 Export PDF Favorites Scan
  • Development of flexible multi-phase barium titanate piezoelectric sensor for physiological health and action behavior monitoring

    Self-powered wearable piezoelectric sensing devices demand flexibility and high voltage electrical properties to meet personalized health and safety management needs. Aiming at the characteristics of piezoceramics with high piezoelectricity and low flexibility, this study designs a high-performance piezoelectric sensor based on multi-phase barium titanate (BTO) flexible piezoceramic film, namely multi-phase BTO sensor. The substrate-less self-supported multi-phase BTO films had excellent flexibility and could be bent 180° at a thickness of 33 μm, and exhibited good bending fatigue resistance in 1 × 104 bending cycles at a thickness of 5 μm. The prepared multi-phase BTO sensor could maintain good piezoelectric stability after 1.2 × 104 piezoelectric cycle tests. Based on the flexibility, high piezoelectricity, wearability, portability and battery-free self-powered characteristics of this sensor, the developed smart mask could monitor the respiratory signals of different frequencies and amplitudes in real time. In addition, by mounting the sensor on the hand or shoulder, different gestures and arm movements could also be detected. In summary, the multi-phase BTO sensor developed in this paper is expected to develop convenient and efficient wearable sensing devices for physiological health and behavioral activity monitoring applications.

    Release date:2024-06-21 05:13 Export PDF Favorites Scan
  • Application of photoplethysmography for atrial fibrillation in early warning, diagnosis and integrated management

    Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia. Early diagnosis and effective management are important to reduce atrial fibrillation‐related adverse events. Photoplethysmography (PPG) is often used to assist wearables for continuous electrocardiograph monitoring, which shows its unique value. The development of PPG has provided an innovative solution to AF management. Serial studies of mobile health technology for improving screening and optimized integrated care in atrial fibrillation have explored the application of PPG in screening, diagnosing, early warning, and integrated management in patients with AF. This review summarizes the latest progress of PPG analysis based on artificial intelligence technology and mobile health in AF field in recent years, as well as the limitations of current research and the focus of future research.

    Release date:2023-12-21 03:53 Export PDF Favorites Scan
  • Performance evaluation of a wearable steady-state visual evoked potential based brain-computer interface in real-life scenario

    Brain-computer interface (BCI) has high application value in the field of healthcare. However, in practical clinical applications, convenience and system performance should be considered in the use of BCI. Wearable BCIs are generally with high convenience, but their performance in real-life scenario needs to be evaluated. This study proposed a wearable steady-state visual evoked potential (SSVEP)-based BCI system equipped with a small-sized electroencephalogram (EEG) collector and a high-performance training-free decoding algorithm. Ten healthy subjects participated in the test of BCI system under simplified experimental preparation. The results showed that the average classification accuracy of this BCI was 94.10% for 40 targets, and there was no significant difference compared to the dataset collected under the laboratory condition. The system achieved a maximum information transfer rate (ITR) of 115.25 bit/min with 8-channel signal and 98.49 bit/min with 4-channel signal, indicating that the 4-channel solution can be used as an option for the few-channel BCI. Overall, this wearable SSVEP-BCI can achieve good performance in real-life scenario, which helps to promote BCI technology in clinical practice.

    Release date:2025-06-23 04:09 Export PDF Favorites Scan
  • Application and progress of wearable devices in epilepsy monitoring, prediction, and treatment

    Epilepsy is a complex and widespread neurological disorder that has become a global public health issue. In recent years, significant progress has been made in the use of wearable devices for seizure monitoring, prediction, and treatment. This paper reviewed the applications of invasive and non-invasive wearable devices in seizure monitoring, such as subcutaneous EEG, ear-EEG, and multimodal sensors, highlighting their advantages in improving the accuracy of seizure recording. It also discussed the latest advances in the prediction and treatment of seizure using wearable devices.

    Release date:2024-08-23 04:11 Export PDF Favorites Scan
3 pages Previous 1 2 3 Next

Format

Content